Please note the following about the screen behavior of devices within the Plixus system:
Confidea FLEX (wired):
- The screen doesn’t dim.
- The screen goes to sleep after 3 hour of inactivity.
- The screen cannot be controlled through API.
- Conditions for resetting the screen saver: touching the screen, meeting state change, opening seat reordering, microphone button press.
Confidea FLEX G4 (wireless):
- The screen dims after 10 seconds.
- The screen goes to sleep after 3 hour of inactivity.
- The screen cannot be controlled through API.
- Conditions for resetting the screen saver: headphone insertion, meeting state change, opening seat reordering, microphone button press.
Lingua ID / Lingua ID-MM:
- The screen doesn’t dim.
- The screen goes to sleep after 1 hours of inactivity.
- The screen cannot be controlled through API.
- Conditions for resetting the screen saver: pressing a physical button, audio detected in the same booth (on the A-channel)
uniCOS:
- The screen doesn’t dim.
- The screen goes to sleep after 2 hours of inactivity. Note that if a uniCOS standby screen is set to a video stream, the device will still go to sleep after 2 hours.
- The screen cannot be controlled through API.
- Conditions for resetting the screen saver: touching the screen or any physical button.